NARTIS-I100-W113
Smart Single-Phase Electricity Meter
-
Name characteristic
Value
-
PRICE CURRENCY
RUB
- Possible communication interfaces - optical port, RS-485, RF, GSM/GPRS, Ethernet, WiFi, LTE, CAN, PLC
- Supported data transfer protocols - Electronic Meter Data Exchange Protocol, Smart Distributed Systems Protocol
- Ability to program and send initiative messages
- 8 rate zones
- Small-sized meter
- Supports information exchange with Pyramid 2.0 software package
- Compartment for a replaceable communication module
- Domestic electronic components
- Code structure of possible meter designs
Code structure of possible meter designs
Meter type:
Casing type:
Version of components:
Accuracy class:
Rated voltage:
Base current:
Maximum current:
Number and type of measuring elements:
Main interface:
Additional interfaces:
Additional features:
- NARTIS-I100-2-3-4-6-7-8-9-10-11-12-13
Meter type:
- NARTIS-I100
Casing type:
- W113 – board-mounted, version 3 (small-sized)
Version of components:
- 2 – confirmation of the meter as a Russian industrial product in accordance with Russian Government Decree No. 719 dated July 17, 2015
- No symbol – components not listed
Accuracy class:
- A1 – accuracy class 1 per GOST 31819.21-2012
- A1R1 – accuracy class 1 per GOST 31819.21-2012 and accuracy class 1 per GOST 31819.23-2012
Rated voltage:
- 230 – 230 V
Base current:
- 5 – 5 А
Maximum current:
- 60А – 60А
- 80А – 80А
- 100 – 100А
Number and type of measuring elements:
- SS – two shunts in the phase current circuit and neutral current circuit
- ST – shunt in the phase current circuit and a current transformer in the neutral current circuit
- TT – two current transformers in the phase current circuit and in the neutral current circuit
Main interface:
- RS485 – RS-485 interface
- RF433/n - 433MHz radio interface, where n is the version number of the interface module
- RF868/n - 868MHz radio interface, where n is the version number of the interface module
- RF2400/n - 2400MHz radio interface, where n is the version number of the interface module
- PL/n - PLC modem, where n is the version number of the interface module
Additional interfaces:
- CAN – CAN interface
- RS232
- RS485 – RS-485 interface
- RF433/n - 433MHz radio interface, where n is the version number of the interface module
- RF868/n - 868MHz radio interface, where n is the version number of the interface module
- RF2400/n - 2400MHz radio interface, where n is the version number of the interface module
- PL/n - PLC modem, where n is the version number of the interface module
- G/n - GSM/GPRS radio interface, where n is the version number of the interface module
- E/n - Ethernet interface, where n is the version number of the interface module
- RFWF – WiFi radio interface
- RFLT – LTE radio interface
- No symbol – no interface
- Supported data transfer protocols:
- P1 – DLMS/COSEM/Electronic Meter Data Exchange Protocol, Smart Distributed Systems Protocol
Additional features:
- E - compartment for a replaceable communication module
- H – magnetic field sensor
- In - digital input, where n is the number of inputs (1 to 4)
- K – load control relay in the current circuit
- L – indicator light
- M – power grid quality measurement
- O – optical port
- Qn - digital output, where n is the number of outputs (1 to 4)
- R – casing unscrewing protection
- U – casing integrity protection
- Vn - electronic seal, where n can take the values:
- 1 – electronic seal on the casing
- 2 – electronic seal on the terminal cover
- 3 – electronic seals on the casing and terminal cover
- 4 - electronic seals on the casing, terminal cover and on the communication module compartment
- Y – protection against replacement of casing parts
- Z/n - backup power source, where n is the version number of the power source
- No symbol – no additional features
- Number of electricity metering directions:
- No symbol – electricity metering in one direction (module-based)
- D – electricity metering in two directions
Contact us for service and warranty issues