USPD SHL-ZB-L
Data Acquisition and Transmission Device with Functions of Telemetry and Telemechanics Controller
The data acquisition and transmission device is designed to receive and store data from electricity meters, utility meters and other digital measuring devices of the information measuring system via digital interfaces, register digital signals, and transmit the information received to higher levels of information computing systems, automated information measuring systems and smart metering systems.
The data acquisition and transmission device is certified to operate with the Pyramid Network information computing system using the Electronic Meter Data Exchange Protocol. It stores active and reactive electrical energy readings from the meter in the forward and reverse directions on an accrual basis over a monthly interval at 1, 2, 3, 4 rates at a depth of at least 5 years, for at least 750 devices.
- The device supports the following open exchange protocols:
- GOST R IEC 60870-5-104-2004
- GOST R IEC 60870-5-101-2006
- Pyramid Network
- Electronic Meter Data Exchange Protocol
The data acquisition and transmission device is certified to operate with the Pyramid Network information computing system using the Electronic Meter Data Exchange Protocol. It stores active and reactive electrical energy readings from the meter in the forward and reverse directions on an accrual basis over a monthly interval at 1, 2, 3, 4 rates at a depth of at least 5 years, for at least 750 devices.
-
Name characteristic
Value
-
PRICE CURRENCY
RUB
- Self-recovery in case of malfunction
- Self-diagnostics
- Digital port to which remote signalling sensors can be connected
- Ethernet and RS-485 interfaces
- ZigBee and GSM communication modules
- SIM card slot
- The data acquisition and transmission device is a recoverable and maintainable device
Code structure of the device
Name:
Casing version (0nD):
Interface type (GnEnUn):
Interface type (ZRn):
Digital inputs (In):
- USPD SHL–ZB–L 0nD.GnEnUn.ZRn.In
Name:
- USPD SHL-ZB-L
Casing version (0nD):
- 0n - casing version, where n is the version number.
- D – built-in display
Interface type (GnEnUn):
- Gn – GSM, where n is the number of interfaces, at least 2 pcs.
- En – Ethernet, where n is the number of interfaces
- W – WiFi
- Un – USB, where n is the number of interfaces, at least 1 pcs.
Interface type (ZRn):
- Z – ZigBee
- Rn – RS–485, where n is the number of interfaces, at least 2 pcs.
- C – RS–232
- P – PLC
Digital inputs (In):
- In – digital inputs, where n is the number of inputs, at least 6 pcs.
Contact us for service and warranty issues